The LoRaWAN water quality EC sensor is a cutting-edge device. It measures the Electrical Conductivity (EC) of water precisely. With LoRaWAN technology, it can transmit data wirelessly over long distances. This sensor is widely used in water quality monitoring, such as in aquaculture, environmental protection, and industrial water systems, providing real-time and accurate EC data for better water management.
Product Model :
LW100-ECPower Supply Mode :
Battery or External DCFrequency :
CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4MAC Version :
LoRaWAN 1.0.3Mode :
OTAA Class A/CWeight :
200gLoRa water quality EC, temperature, salinity sensor is a water conductivity sensor used to measure the conductivity of solutions. It has an automatic temperature compensation function, which can compensate the conductivity of the current temperature to the specified temperature. It can be widely used for continuous monitoring of the conductivity value of aqueous solutions in fields such as water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, and tap water. Supports LoRa TDMA self-organizing network and standard LoRaWAN protocol.
Technical Parameter
Power Supply | ER26500 Li-SOCl2 8500 mAh battery,3.6V | |
Weight | 200g | |
Operating emperature | -20~+80°C | |
Sensor parameters | Temperature | -5~+80°C |
EC |
Electrode constant K=1:1~2000us/cm Electrode constant K=10:10~20000us/cm |
|
Salinity |
Electrode constant K=1:0~1000mg/L Electrode constant K=10:0~11476mg/L |
|
TDS |
Electrode constant K=1:0~1100mg/L Electrode constant K=10:0~13400mg/L |
|
Typical Accuracy | Temperature | ±0.1℃ |
EC |
Electrode constant K=1:0.1 μ s/cm; Electrode constant K=10:1 us/cm; |
|
Salinity | - | |
Temperature Compensation Range | -5~+80℃ (default compensation temperature is 25℃) | |
Temperature Compensation Coefficient |
Default 0.02 |
|
EC Equipment Working Conditions |
-20~+80℃ |
|
Pressure Resistance |
0.6MPa |
|
EC Transmitter Line length |
Default 5m (other lengths can be customized) |
|
Frequency |
CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
|
Mode |
OTAA Class A |
|
Reporting cycle |
60min(Default ) |
|
Battery Life |
≤3 years (Depending on the reporting cycle) Note: Due to the high power consumption of EC sensor, it is not recommended to use short cycle data reporting. |
|
Communication Protocol |
LoRaWAN,LoRa TDMA Networking |
|
Equipment information (Reference) |
AppEUI:0000000000000001 DevEUI:aaaa202404150001 AppKey:00001111222233334444555566667777 MAC Version:LoRaWAN 1.0.3
|
EC Transmitter Size and Installation
1. Submerged installation: The lead wire of the equipment is passed through the waterproof pipe, and the 3/4 thread on the top of the equipment is connected with the 3/4 thread of the waterproof pipe with raw material tape. Make sure that the top of the equipment and the equipment lines are free of water.
2. Pipe Installation: Connect to the pipe through the 3/4 thread of the device.